This is a 2-channel system for VLBI
observations. The whole receiver was reconditioned in late 2006.
| Frequency
[GHz] |
Channel |
Polarisation |
Tcal [K] |
Tsys [K] |
Sensitivity [K/Jy] |
SEFD [Jy] |
Aperture Eff. [%] |
TMB/S [K/Jy] |
Main Beam Eff. [%] |
FWHM [arcsec] |
Last update |
| 42.0 |
A |
LCP |
13.8 |
108
|
0.53 |
196
|
19 |
1.5 |
36 |
19.8 |
Mar 2009 |
| 42.0 |
B |
RCP |
12.2 |
131
|
0.53 |
248
|
19 |
1.5 |
35 |
19.8 |
Mar 2009 |
|
normalized, opacity corrected gain curve
(G = A0 + A1·Elv + A2·Elv2)
|
Observed in |
|
A0 = 0.8806 A1 =
5.8673E-3
A2 = -7.1243E-05 |
Dec 2007 |
A0 = 0.8800 A1 =
6.9970E-3
A2 = -1.0210E-04 |
Mar 2009 |
Comments:
- For informations
about the old parameters please contact Uwe Bach (ubach_at_mpifr.de).
- Opacity correction was done with a zenith opacity of 0.08.
Typical zenith opacities under good weather conditions are around 0.07
to 0.1 at 42 GHz
|