This is a 4-channel system mainly for VLBI
and continuum observations.
| Frequency
[GHz] |
Channel |
Polarisation |
Tcal [K] |
Tsys [K] |
Sensitivity [K/Jy] |
SEFD [Jy] |
Aperture Eff. [%] |
TMB/S [K/Jy] |
Main Beam Eff. [%] |
FWHM [arcsec] |
Last update |
| 8.410 |
I (BB) |
RCP |
2.5 |
22 |
1.35 |
18 |
45 |
2.6 |
49 |
81.7 |
Jul 2008 |
| 8.410 |
J (BB) |
LCP |
2.5 |
22 |
1.35 |
18 |
45 |
2.6 |
49 |
81.7 |
Jul 2008 |
| 8.550 |
I (BB) |
RCP |
2.5 |
23 |
1.35 |
18 |
46 |
2.6 |
50 |
80.6 |
Jul 2008 |
| 8.550 |
J (BB) |
LCP |
2.5 |
25 |
1.35 |
19 |
46 |
2.6 |
50 |
80.6 |
Jul 2008 |
|
normalized Gain curve
(G = A0 + A1·Elv + A2·Elv2)
|
Observed in |
|
A0 = 0.97453 A1 = 1.192E-3
A2 = -1.389E-5 |
Dec 2001 |
|
A0 = 0.99500
A1 = 4.3434e-04
A2 = -1.0562e-05 |
Feb 2007 |
Comments:
- All values are valid for the new receiver which was
installed in September 2001. If you
need data for the old one, please contact akraus_at_mpifr-bonn.mpg.de.
- Note that (against our usual designation) Channel A is RCP
and B LCP!
- The new gain curve (Feb 2007) was corrected for opacity.
- If no other information about the opacity is available a typical zenith
tau value of about 0.018 should do a good job.
|